MCB Overcurrent circuit breaker Icn=6000A 3P B 32A QuickConnect Hager MBS332
- MCB Overcurrent circuit breaker Icn=6000A 3P B 32A QuickConnect Hager MBS332
HAGERHager stands for excellent quality and the pursuit of perfection. Innovation and systematic development of our products and systems are the basic features of Hager. Our constant goal is to implement new design patterns and improvements, in order to be at the forefront of continuous technical progress. Thanks to their high quality, Hager products are known throughout the world. This quality can be seen and sensed in the design. A unique, unmistakable and clear image informs the customer that the product is part of the Hager "family".
We build our leadership position based on a commitment to creativity and the ability to surprise customers with unique and technologically advanced solutions. Our ambition is to combine modern technologies with interesting design.Our products are unique, there is no glamour in them. Important for us is the ideal form, and above all, functionality. Simple to install and easy to use. Simply Hager!
HAGER INNOVATIONSWhen implementing innovations and new technologies, we are always guided by the needs of our customers. Thanks to this, thousands of customers in more than 95 countries around the world have already trusted us. Hager systems and solutions do not stand still but are constantly developing. They are becoming more and more recognizable. With Hager solutions, you get everything you need to create a Smart Home from one supplier
EASY
INSTALLATIONSimple installation, ease of use, intuitive interface, modular structure and durability are the values that guarantee the highest quality of Hager brand systems. All Hager solutions used for home automation are based on the most universal and open bus standard: KNX. It was pioneered in the 1990s by leading European manufacturers and is now used worldwide
MCB overcurrent circuit breaker Icn=6000A 3P B 32A QuickConnect Hager MBS332
Design
Number of protected poles: | 3 |
Number of poles: | 3 P |
Pole arrangement: | 3 P |
Trigger characteristics: | B |
Electrical characteristics
Frequency: | 50/60 Hz |
Rated short circuit switching capacity Icn: | 6 kA |
Supply voltage type: | AC |
Voltage
Rated withstand surge voltage Uimp: | 4000 V |
Current
400V breaking capacity (NF EN 60947-2): | 10 kA |
Rated short circuit breaking capacity Icn below 400V AC according to IEC 60898-1: | 6 kA |
Rated operational short-circuit breaking current Ics: | 6 kA |
Breaking capacity 1P at 400V (EN 60947-2): | 3 kA |
Breaking capacity 415V (NF EN 60947-2): | 10 kA |
Min/max value of AC tripping current of delay-free protection: | 3/5 In |
Min./max. value of DC current of tripping the delay-free protection: | 4/7 In |
Min/max value of the AC current of tripping the delayed protection: | 1.13/1.45 In |
Min./max. value of DC current of tripping the delayed protection: | 1.13/1.45 In |
Current / Temperature
Rated current at -15°C: | 38,6 A |
Rated current at -20°C: | 39,3 A |
Rated current at 0°C: | 36,5 A |
Rated current at 10°C: | 35,1 A |
Rated current at -10°C: | 37,9 A |
Rated current at 15°C: | 34,4 A |
Rated current at 20°C: | 33,6 A |
Rated current at 25°C: | 32,8 A |
Rated current at -25°C: | 39,9 A |
Rated current at 30°C: | 32 A |
Rated current at 35°C: | 31,1 A |
Rated current at 40°C: | 30,3 A |
Rated current at 45°C: | 29,3 A |
Rated current at 5°C: | 35,8 A |
Rated current at -5°C: | 37,2 A |
Rated current at 50°C: | 28,4 A |
Rated current at 55°C: | 27,4 A |
Rated current at 60°C: | 26,4 A |
Rated current at 65°C: | 25,3 A |
Rated current at 70°C: | 24,2 A |
Current correction factor
Correction factor of the delay-free trigger at 100 Hz: | 1,1 |
Correction factor of the undelayed trigger at 200 Hz frequency: | 1,2 |
Correction factor of the undelayed trigger at 400 Hz: | 1,5 |
Correction factor of the undelayed trigger at 60 Hz: | 1 |
Correction factor of nominal current for 2 devices installed side by side: | 1 |
Correction factor of nominal current for 3 apparatus installed side by side: | 0,95 |
Correction factor of significant current for 4 or 5 apparatuses installed next to each other: | 0,9 |
Current crest factor for 6 apparatuses installed side by side: | 0,85 |
Selectivity
Min. value of aM upstream fuse block rated current for short-circuit selectivity: | 40 A |
Min. current rating of gL upstream for short circuit selectivity: | 40 A |
Max. fuse rating current aM downstream for short circuit selectivity: | 4 A |
Max. fuse rating gL downstream for short-circuit selectivity: | 10 A |
Power
Power loss per pole for rated current: | 4,9 W |
Maximum power loss per pole according to standard: | 6 W |
Total power loss for rated current: | 13 W |
Durability
Electrical endurance (number of cycles): | 4000 |
Mechanical endurance (number of cycles): | 20000 |
Dimensions
Product depth: | 70 mm |
Product height: | 83.4 mm |
Product width: | 52.5 mm |
Installation / Mounting
Adapted for flush mounting: | yes |
Connection
Output terminal capacity for flexible cable (wire): | 1/25 mm² |
Input terminal capacity for flexible cable (wire): | 1/25 mm² |
Output terminal capacity for rigid wire (wire): | 1/35 mm² |
Input terminal capacitance for rigid wire (wire): | 1/35 mm² |
Phase bus with access terminal compatibility: | KDNxxx |
Connection type: | Quick Connect |
Equipment
Standard
Standard: | EN 60898-1 |
European WEEE Directive: | applies to |
Safety
Degree of protection: | IP20 |
Operating conditions
Degree of contamination according to IEC 60664 / IEC 60947-2: | 2 |
Energy limitation class I²t: | 3 |
Hager MBS332
Degree of protection (IP)
Certificate/Attestation/Standard
Do you need help? Do you have any questions?Ask a question and we'll respond promptly, publishing the most interesting questions and answers for others.