Dear customer! If you have any questions or need advice, please contact us: office@reeline.uk
Free delivery from £300.00
Save to shopping list
Create a new shopping list
3-phase current transformer 100/5 1.5VA TP-100-5 F&F
3-phase current transformer 100/5 1.5VA TP-100-5 F&F
3-phase current transformer 100/5 1.5VA TP-100-5 F&F
3-phase current transformer 100/5 1.5VA TP-100-5 F&F
3-phase current transformer 100/5 1.5VA TP-100-5 F&F
3-phase current transformer 100/5 1.5VA TP-100-5 F&F

3-phase current transformer 100/5 1.5VA TP-100-5 F&F

  • 3-phase current transformer 100/5 1.5VA TP-100-5 F&F
EAN: 5902431671055
£29.33
/ pcs. gross
The lowest price before discount: / pcs.
Express checkout 1-Click(without registration)
Product to order
Product to order
30 days for easy returns
Safe shopping
The quantity in stock requires confirmation

3-phase current transformer 100/5 1,5VA TP-100-5 F&F

Product description

Three-phase. current transformer 100/5. power 1,5 VA.
The 3-phase current transformer (3-in-1) is used for indirect measurement of three-phase currents. Its design allows it to be mounted directly on the outputs of power disconnectors (ABB Isomax series, Merlin Gerlin NS series and analogous) saving installation time and space in the switchgear.

Operation
The wire with the measured current passes through the main hole of the transformer(P1/P2), which is equivalent to one winding of the primary winding. The terminals of the secondary winding S1 and S2 are connected to the terminals of the measuring circuit of the control or measuring device.
The ratio of the intensities of the currents in the two windings is a constant quantity and is called the current ratio: IPn/ISn=N, where IPn - rated primary current; ISn - rated secondary current; N - value of transmission ratio. From the value of the current flowing through the secondary winding, the value of the current flowing through the primary winding can be determined: ISm*N=IPm, where ISm - measured primary current; IPm - measured secondary current.

Note!
Recommended to connect the secondary system with a wire with a diameter of not less than 2.5 mm².
Recommended grounding of the S2 terminal.
Prohibit disconnection of the secondary circuit during operation of the transformer (possibility of high voltage resulting in paralysis of persons or damage to the device).

Technical data:

Type three-phase
Construction with closed core
Transmission lp/ls 100/5
Class 1
Power [VA] 1.5 VA
Frequency 50÷60 Hz
Maximum operating voltage 720 V AC
Standard no IEC 60044-1
Secondary nominal current Is 5 A
Insulation breakdown voltage 3 kV/1 min.
P1/P2 hole dimensions 15 mm x 21 mm
Weight 0.452 kg
Safety factor FS ? 5
Connection S1/S2 screw terminals 4 mm²
Dimensions WxHxD [mm] 76.5 mm x 74 mm x 80 mm
Thermal short-circuit current (lth) 60 x In
Dynamic short-circuit current (Idyn) 2.55 x lth
Tightening torque 0.5 Nm
Working temperature -5÷40°C
Mounting position vertical/horizontal
Mounting dIN rail / board / cable
Degree of protection IP20

TP-100-5 F&F

Brand
Symbol
TP-100-5 F&F
Producer code
5902431671055
Warranty
Degree of protection (IP)
IP20
Do you need help? Do you have any questions?Ask a question and we'll respond promptly, publishing the most interesting questions and answers for others.
Ask a question
If this description is not sufficient, please send us a question to this product. We will reply as soon as possible. Data is processed in accordance with the privacy policy. By submitting data, you accept privacy policy provisions.
2 years
2 years
Write your opinion
Your opinion:
5/5
Add your own product photo:
pixel