Dear customer! If you have any questions or need advice, please contact us: office@reeline.uk
Free delivery from £300.00
Save to shopping list
Create a new shopping list
Current transformer 50/5 2,5VA TI-50-5 F&F
Current transformer 50/5 2,5VA TI-50-5 F&F
Current transformer 50/5 2,5VA TI-50-5 F&F
Current transformer 50/5 2,5VA TI-50-5 F&F
Current transformer 50/5 2,5VA TI-50-5 F&F
Current transformer 50/5 2,5VA TI-50-5 F&F

Current transformer 50/5 2,5VA TI-50-5 F&F

  • Current transformer 50/5 2,5VA TI-50-5 F&F
EAN: 5908312599692
£16.00
/ pcs. gross
The lowest price before discount: / pcs.
Express checkout 1-Click(without registration)
Product available
Product available
30 days for easy returns
Safe shopping
The quantity in stock requires confirmation

Current transformer 50/5 2,5VA TI-50-5 F&F

Product description

Current Transformer 50/5 Power of 2.5 VA.
The current transformer is used for proportional change of large current intensities to lower values, adapted to the measuring ranges of control and measuring devices.

Operation
The wire with the measured current passes through the main hole of the transformer(P1/P2), which is equivalent to one winding of the primary winding. The terminals of the secondary winding S1 and S2 are connected to the terminals of the measuring circuit of the control or measuring device.
The ratio of the intensities of the currents in the two windings is a constant quantity and is called the current ratio: IPn/ISn=N, where IPn - rated primary current; ISn - rated secondary current; N - value of transmission ratio. From the value of the current flowing through the secondary winding, the value of the current flowing through the primary winding can be determined: ISm*N=IPm, where ISm - measured primary current; IPm - measured secondary current.

Note!
Recommended to connect the secondary system with a wire with a diameter of not less than 2.5 mm².
Recommended grounding of the S2 terminal.
Prohibit disconnection of the secondary circuit during operation of the transformer (possibility of high voltage resulting in paralysis of persons or damage to the device).

Technical data:
Type single-phase
Construction with closed core
Transmission lp/ls 50/5
Class 1
Power [VA] 2.5 VA
Frequency 50÷60 Hz
Maximum operating voltage 0,66 kV AC
Standard no IEC 60044-1
Nominal secondary current Is 5 A
Insulation breakdown voltage 3 kV/1 min.
P1/P2 hole dimensions Ø22 mm
Weight 0.135 kg
Safety factor FS ? 5
Dimensions WxH [mm] 87.5 mm x 104 mm
S1/S2 connection screw terminals 4 mm²
Tightening torque 0.5 Nm
Working temperature -5÷40°C
Mounting position vertical/horizontal
Mounting board/busbar
Degree of protection IP20

TI-50-5 F&F

Brand
Symbol
TI-50-5 F&F
Producer code
5908312599692
Warranty
Degree of protection (IP)
IP20
Do you need help? Do you have any questions?Ask a question and we'll respond promptly, publishing the most interesting questions and answers for others.
Ask a question
If this description is not sufficient, please send us a question to this product. We will reply as soon as possible. Data is processed in accordance with the privacy policy. By submitting data, you accept privacy policy provisions.
2 years
2 years
Write your opinion
Your opinion:
5/5
Add your own product photo:
pixel