Dear customer! If you have any questions or need advice, please contact us: office@reeline.uk
Free delivery from £300.00
Save to shopping list
Create a new shopping list
Timing relay 10-function 8A 1xNO/NC 12-264V AC/DC PCS-516UNI F&F
Timing relay 10-function 8A 1xNO/NC 12-264V AC/DC PCS-516UNI F&F
Timing relay 10-function 8A 1xNO/NC 12-264V AC/DC PCS-516UNI F&F
Timing relay 10-function 8A 1xNO/NC 12-264V AC/DC PCS-516UNI F&F
Timing relay 10-function 8A 1xNO/NC 12-264V AC/DC PCS-516UNI F&F
Timing relay 10-function 8A 1xNO/NC 12-264V AC/DC PCS-516UNI F&F

Timing relay 10-function 8A 1xNO/NC 12-264V AC/DC PCS-516UNI F&F

  • Timing relay 10-function 8A 1xNO/NC 12-264V AC/DC PCS-516UNI F&F
EAN: 5908312591429
£26.38
/ pcs. gross
The lowest price before discount: / pcs.
Express checkout 1-Click(without registration)
Product available
Product available
30 days for easy returns
Safe shopping
The quantity in stock requires confirmation

Timing relay 10-function 8A 1xNO/NC 12-264V AC/DC PCS-516UNI F&F

Product description

10-function. With START and RESET inputs.
Timing relays are used for timing control in industrial and home automation systems (e.g.: ventilation, heating, lighting, signaling, etc.).

Operation
The relay performs the selected work function according to the set time regime. The selection of a specific time range and the relay's operation function is based on setting the appropriate combination of rotary code switches.


Work functions




DELAYED SWITCHING ON
When the supply voltage is applied (green LED U is lit), the output remains open and the set operation time "t" is measured. After the time "t" is measured, the output is switched on (red LED lit). Re-execution of the relay operation mode is possible after disconnecting the supply voltage and switching it on again.



DELAYED DEACTIVATION
Until the relay is switched on, the output remains open. When the supply voltage is applied (green LED is lit), the output will be closed
and the set operation time "t" is measured (red LED lit). Re-execution of the relay operation mode is possible after disconnecting the supply voltage and switching it on again.

FF PCS-516 diag C.gif

DELAYED SWITCHING - CYCLIC
The operation mode of delayed switching realized cyclically in equal intervals of the set operation time and interval.

FF PCS-516 diag D.gif

DELAYED SWITCH-OFF - CYCLIC
The mode of operation of delayed switch-off realized cyclically in equal intervals of the set operating time and interval.

FF PCS-516 diag E.gif

Generating a pulse of 0.5 s after the preset time "t".


FF PCS-516 diag F.gif

Generation of a single pulse at time "t" with a rising edge of the START signal. During timing, the system does not respond to START pulses.

FF PCS-516 diag G.gif

Generation of a single pulse at time "t" on the falling edge of the START signal. During timing, the system does not respond to START pulses.

FF PCS-516 diag H.gif

Delay at shutdown with the possibility of sustaining. The rising edge of the START signal causes the relay to turn on, while the falling edge causes the start of timing. Administering the START signal during the timekeeping results in extending the cycle for another time "t" with a falling edge.

FF PCS-516 diag I.gif

Generation of a single 0.5 s pulse after time "t" triggered by the falling edge of the START signal.

FF PCS-516 diag K.gif

Switching off the relay for the specified time "t" with the rising edge of the START signal. During the timing, the system does not respond to the START signal.

Attention!
* Applying RESET voltage during the execution of the function causes:
- for functions A, B, C, D, F realization of the operation mode from the beginning.
- for functions F, G, H, I return the relay to its initial state and wait for START signal.
- for function K permanent switching of the relay contact in position 11-12.
* Setting the rotary switch of the time range in position:
* When the power is on, the system does not respond to a change in the time range setting.
* Operation with the newly set time range occurs after the power is turned off and on again.
* When the power is turned on, smooth adjustment of the time within the set time range is possible.

Time ranges

0,1s: 0,1÷1,2 s
1s: 1÷12 s
10s: 10÷120 s
1m: 1÷12 min.
10m: 10÷120 min.
2h: 2÷24 hrs.
1d: 1÷12 days (24÷288 hrs)
2d: 2÷24 days (48÷576 hrs)

ON - when power is on, causes permanent switching of the contact in 11-12 position.
OFF - when the power is on, it causes permanent switching of the contact to the 11-10 position.

Technical data:

Supply voltage 12÷264 V AC/DC
Operation mode multifunctional
Executive element relay
Maximum load current 8 A
Contact configuration 1 × NO/NC
Contact separation YES
Tripping delay 50 ms
Control pulse current less than 1 mA
Contact status indication LED red
Operation time - adjustable 0.1 s ÷ 576 hrs.
Power supply signaling LED green
Connection screw terminals 2.5 mm²
Tightening torque 0,4 Nm
Power consumption 0,8 W
Operating temperature -25 ÷ 50 °C
Dimensions 1 module (18 mm)
Mounting on a 35 mm rail
Protection class IP20

PCS-516UNI F&F

Brand
Symbol
PCS-516UNI F&F
Producer code
5908312591429
Model
Time relay
Degree of protection (IP)
IP20
Power
0,8 W
Do you need help? Do you have any questions?Ask a question and we'll respond promptly, publishing the most interesting questions and answers for others.
Ask a question
If this description is not sufficient, please send us a question to this product. We will reply as soon as possible. Data is processed in accordance with the privacy policy. By submitting data, you accept privacy policy provisions.
Write your opinion
Your opinion:
5/5
Add your own product photo:
pixel