Time relay PCU-511 F&F

Product description

1P contact.
Timing relays are used for time control in industrial and home automation systems (e.g.:ventilation, heating, lighting, signaling, etc.).

Operation
Functions:
*DELAYED SHUTDOWN (A)
Until the relay is switched on, the contact remains in position 11-10 (3-5 for PCU-511 UNI). When the supply voltage is applied, the contact is switched to position 11-12 (3-7 for PCU-511 UNI) and the set operation time t is measured. After the time t is measured, the contact returns to position 11-10 (3-5 for PCU-511 UNI). Re-execution of the relay operation mode is possible after the power supply voltage is disconnected and switched on again.
*DELAYED ACTIVATION (B)
Before and after the supply voltage is applied, the contact remains in the 11-10 position (3-5 for PCU-511 UNI) and the set operation time t is measured. After the time t is measured, the contact switches to the 11-12 position (3-7 for PCU-511 UNI). Re-execution of the relay operation mode is possible after the power supply voltage is disconnected and switched on again.
*DELAYED DEACTIVATION - CYCLIC (C)
The operation mode of delayed deactivation realized cyclically at equal intervals of the set operation time and interval.
*DELAYED SWITCH-ON - CYCLIC (D)
The mode of operation of delayed switch-on realized cyclically in equal intervals of the set operating time and interval.

Attention!
* When the power is on, the system does not react to a change in the time range setting.
* Operation with the newly set time range is carried out after the power supply is switched off and on again.
* When the power is switched on in the set time range, it is possible to smoothly adjust the time within the range of the time setting value.

Time ranges

0,1s : 0.1÷1.2 sec.
1s : 1÷12 sec.
10s : 10÷120 sec.
1m : 1÷12 min.
10m : 10÷120 min.
2h : 2÷24 hrs.
1d : 1÷12 days (24÷288 hrs)
2d : 2÷24 days (48÷576 hrs)

oN - when power is on, causes permanent contact switching in position 11-12.
oFF - when the power is on, it causes permanent switching of the contact in the 11-10 position.

Technical data:

Supply voltage 230 V AC
Operation mode delayed switch-off, delayed switch-on, cyclic operation
Executive element relay
Maximum load current 8 A
Contact configuration 1 × NO/NC
Contact separation YES
Tripping delay 50 ms
Contact status indication LED red
Operation time - adjustable 0.1 s ÷ 576 hrs.
Power supply signaling LED green
Connection screw terminals 2.5 mm²
Tightening torque 0,4 Nm
Power consumption 0,8 W
Operating temperature -25 ÷ 50 °C
Dimensions 1 module (18 mm)
Mounting on a 35 mm rail
Protection class IP20

PCU-511 F&F

Brand
Symbol
PCU-511 F&F
Producer code
5908312595410
Warranty
Model
Time relay
Degree of protection (IP)
IP20
Power
0,8 W
Do you need help? Do you have any questions?Ask a question and we'll respond promptly, publishing the most interesting questions and answers for others.