Dear customer! If you have any questions or need advice, please contact us: office@reeline.uk
Free delivery from £300.00
Save to shopping list
Create a new shopping list
Three-state liquid level control relay, with sensitivity adjustment, with PZ2 probes (4pcs), 3×1P contacts, I=2×16A, 3 modules, PZ-831 RC, F&F
Three-state liquid level control relay, with sensitivity adjustment, with PZ2 probes (4pcs), 3×1P contacts, I=2×16A, 3 modules, PZ-831 RC, F&F
Three-state liquid level control relay, with sensitivity adjustment, with PZ2 probes (4pcs), 3×1P contacts, I=2×16A, 3 modules, PZ-831 RC, F&F
Three-state liquid level control relay, with sensitivity adjustment, with PZ2 probes (4pcs), 3×1P contacts, I=2×16A, 3 modules, PZ-831 RC, F&F
Three-state liquid level control relay, with sensitivity adjustment, with PZ2 probes (4pcs), 3×1P contacts, I=2×16A, 3 modules, PZ-831 RC, F&F
Three-state liquid level control relay, with sensitivity adjustment, with PZ2 probes (4pcs), 3×1P contacts, I=2×16A, 3 modules, PZ-831 RC, F&F

Three-state liquid level control relay, with sensitivity adjustment, with PZ2 probes (4pcs), 3×1P contacts, I=2×16A, 3 modules, PZ-831 RC, F&F

  • Three-state liquid level control relay, with sensitivity adjustment, with PZ2 probes (4pcs), 3×1P contacts, I=2×16A, 3 modules, PZ-831 RC, F&F
EAN: 5908312592549
£79.14
/ pcs. gross
The lowest price before discount: / pcs.
Express checkout 1-Click(without registration)
Product to order
Product to order
30 days for easy returns
Safe shopping

PZ-831 RC liquid level control relay

PZ-831RC

Tri-state. With sensitivity adjustment.
PZ-831 RC relays are used to detect the presence of electrically conductive liquids at the levels of the flood probes mounted. They allow to maintain the minimum and maximum states of the controlled liquid within the range set by the user.

Operation
In the dry state (all probes open) all relay contacts are open. Short-circuiting the base probe COM and another level probe with liquid will close the relay contact assigned to the probe, e.g., when the first level probe R1 is flooded (short-circuiting the base probe COM and the level probe R1), contact 11-12 will be closed. Analogously for level probes R2 and R3. Lowering of the liquid level below the level probe (opening of COM and level probe) will open the contact assigned to the probe.

Probe connection method
Electrode probes (4 pcs.) connected by cable with a wire diameter up to 1 mm? and a maximum length of 100 m.

Note!
Terminals 3-4-5-6 are galvanically separated from the network.

Technical data

Supply voltage

230 V AC

Executive element

3 x relay

Maximum load current

3 × 8 A

Contact configuration

3 × NO

Contact separation

YES

Sensitivity - adjustable

1÷180 k?

Voltage of measurement outputs

6 V

Type of flooding probe

4 x PZ2

Probe terminals

separated from the mains by a transformer

Switching delay of contacts

max. 2 s

Connection

screw terminals 4.0 mm?

Tightening torque

0.5 Nm

Power consumption

1,1 W

Operating temperature

-25 ÷ 50 °C

Dimensions

3 modules (52,5 mm)

Mounting

on a 35 mm rail

Protection degree

IP20

Brand
Symbol
PZ-831RC/FIF
Producer code
5908312592549
Warranty
Manufacturer's code
PZ-831RC
Degree of protection (IP)
IP20
Power
1,1 W
Do you need help? Do you have any questions?Ask a question and we'll respond promptly, publishing the most interesting questions and answers for others.
Ask a question
If this description is not sufficient, please send us a question to this product. We will reply as soon as possible. Data is processed in accordance with the privacy policy. By submitting data, you accept privacy policy provisions.
2 years
2 years
Write your opinion
Your opinion:
5/5
Add your own product photo:
pixel